All-In-One-DD

Aluminum coating on detector side
Multipurpose AFM Probe with 4 Different Cantilevers
Add

Multipurpose AFM Probe with 4 Different Cantilevers and Conductive Diamond Tip Coating

AFM Tip

SHAPE
Rotated
HEIGHT
17 µm (15 - 19 µm)*
SETBACK
15 µm (10 - 20 µm)*
RADIUS
250 nm
HALF CONE ANGLE
20°-25° along cantilever axis, 25°-30° from side, 10° at the apex

4 AFM Cantilevers

Cantilever A - Contact Mode
 Beam
 0.5 N/m (0.2 - 0.9 N/m)*
 19 kHz (16 - 24 kHz)*
 500 µm (490 - 510 µm)*
 30 µm (25 - 35 µm)*
 2.7 µm (1.7 - 3.7 µm)*
Cantilever B - Force Modulation
 Beam
 6.5 N/m (3 - 12 N/m)*
 110 kHz (80 - 140 kHz)*
 210 µm (200 - 220 µm)*
 30 µm (25 - 35 µm)*
 2.7 µm (1.7 - 3.7 µm)*
Cantilever C - Soft Tapping
 Beam
 18 N/m (8 - 35 N/m)*
 200 kHz (140 - 260 kHz)*
 150 µm (140 - 160 µm)*
 30 µm (25 - 35 µm)*
 2.7 µm (1.7 - 3.7 µm)*
Cantilever D - Tapping Mode
 Beam
 100 N/m (48 - 190 N/m)*
 450 kHz (230 - 600 kHz)*
 100 µm (90 - 110 µm)*
 50 µm (45 - 55 µm)*
 2.7 µm (1.7 - 3.7 µm)*
* typical range

Coating

Boron doped polycrystalline diamond tip coating, 100 nm thick; Aluminum coating on detector side of the cantilever, 30 nm thick.

Alignment Grooves

none

Additional Info

Versatile monolithic silicon AFM probe with 4 different AFM cantilevers on a single AFM holder chip for various applications: contact mode, force modulation mode, soft tapping mode and high frequency tapping / non-contact mode and electric modes such as: scanning capacitance microscopy (SCM), electrostatic force microscopy (EFM), Kelvin probe force microscopy (KFM), scanning probe lithography and conductive atomic force microscopy (C-AFM).

The doped polycristalling diamond AFM tip coating provides unprecedented hardness and durability, as well as electridcal conductivity for demanding electrical applications. The resulting AFM tip radius is in the range 100-250nm.

The rotated AFM tips allow for more symmetric representation of high sample features.

The AFM holder chip fits most commercial AFM systems as it is industry standard size.

The main advantage of this product compared to regular, single-cantilever AFM probes is the freedom to choose the right AFM cantilever for each application in the very last moment. You do not need to stock various AFM probe types any more. Nevertheless, this product is not meant as a substitution to comparable single-cantilever AFM probes, because the geometry of each one of the All-In-One AFM cantilevers differs from the geometry of the comparable specialized single-cantilever AFM probes.

Please note that the aluminum back side coating is not suitable for measurements in liquids!

Inquiry(0)